How to integrate Smartsheet using Alteryx
Learn how to quickly and efficiently connect Smartsheet with Alteryx for smooth data access.
Read and write Smartsheet data effortlessly. Integrate, manage, and automate sheets, rows, and reports — almost no coding required. You can do it all using the high-performance Smartsheet ODBC Driver for Alteryx (often referred to as the Smartsheet Connector). We'll walk you through the entire setup.
Ready to dive in? Download the product to jump right in, or follow the step-by-step guide below to see how it works.
Create data source using Smartsheet ODBC Driver
Step-by-step instructions
To get data from Smartsheet using Alteryx, we first need to create an ODBC data source. We will later read this data in Alteryx. Perform these steps:
-
Download and install ODBC PowerPack (if you haven't already).
-
Search for
odbcand open the ODBC Data Sources (64-bit):
-
Create a User data source (User DSN) based on the ZappySys API Driver driver:
ZappySys API Driver
- Create and use a User DSN if the client application runs under a User Account. This is the ideal option at design time (e.g., when developing in Visual Studio). Use it for both types of applications (64-bit and 32-bit).
- Create and use a System DSN if the client application runs under a System Account (e.g., as a Windows Service). This is usually the required option in a production environment. If your Windows Service is a 32-bit application, you must use the 32-bit ODBC Data Source Administrator to configure this
-
When the Configuration window appears give your data source a name if you haven't done that already, then select "Smartsheet" from the list of Popular Connectors. If "Smartsheet" is not present in the list, then click "Search Online" and download it. Then set the path to the location where you downloaded it. Finally, click Continue >> to proceed with configuring the DSN:
SmartsheetDSNSmartsheet
-
Now it's time to configure the Connection Manager. Select Authentication Type, e.g. Token Authentication. Then select API Base URL (in most cases, the default one is the right one). More info is available in the Authentication section.
Smartsheet authentication
OAuth Walkthrough
Apps connect to Smartsheet using OAuth 2.0 to authenticate and authorize users. If you are building an app, this documentation will walk you through the steps you need to authenticate your users. The Smartsheet SDKs contain APIs for OAuth 2.0.
NOTE: For users of apps like AWS AppFabric, you will need a Tenant ID. You can find your Tenant ID in Admin Center under Security & Controls. There is a Smartsheet Tenant ID pane.
First Steps
Before you can start using OAuth 2.0 with your app, Smartsheet needs the following information:
- You must register with Smartsheet to get a developer account*. The developer account gives you access to "Developer Tools", which is where you manage your app.
- In "Developer Tools", complete any required fields in your developer profile.
- In "Developer Tools", register your app so Smartsheet can assign a client Id and a client secret to the app.
- Review the list of access scopes. You'll need to choose which ones your app needs to get to a user's Smartsheet data, and then ask the user to consent to that access.
- After you've worked through these steps, you'll be ready to implement the OAuth Flow.
Open Developer Tools
- Log in to Smartsheet with your developer account.
- Click the "Account" button in the lower-left corner of your Smartsheet screen, and then click "Developer Tools".
- Do one of the following:
- If you need to register an app, click "Create New App".
- If you need to manage an app, click "view/edit" for the app.
Register Your App Using Developer Tools
- Log in to Smartsheet with your developer account.
- Click the "Account" button in the upper-right corner of your Smartsheet screen, and then click "Developer Tools".
- In the "Create New App" form, provide the following information:
- Name: the name the user sees to identify your app
- Description: a brief description intended for the user
- URL: the URL to launch your app, or the landing page if not a web app
- Contact/support: support information for the user
- Redirect URL: also known as a callback URL. The URL within your application that will receive the OAuth 2.0 credentials After you click "Save", Smartsheet assigns a client Id and secret to your app. Make a note of these Ids for the next steps; however, you can always look them up again in "Developer Tools".
API Connection Manager configuration
Just perform these simple steps to finish authentication configuration:
-
Set Authentication Type to
OAuth (Dynamic Token) [OAuth] - Optional step. Modify API Base URL if needed (in most cases default will work).
- Fill in all the required parameters and set optional parameters if needed.
- Press Generate Token button to generate the tokens.
- Finally, hit OK button:
SmartsheetDSNSmartsheetOAuth (Dynamic Token) [OAuth]https://api.smartsheet.com/2.0Required Parameters ClientId Fill-in the parameter... ClientSecret Fill-in the parameter... Scope Fill-in the parameter... Optional Parameters RetryMode RetryWhenStatusCodeMatch RetryStatusCodeList 429|503 RetryCountMax 5 RetryMultiplyWaitTime True
Smartsheet authentication
Raw Token Requests
If you want to get started quickly, or are developing a standalone application that can run with your credentials, follow these instructions:
- Click the "Account" button in the lower-left corner of the Smartsheet screen, and then click "Personal Settings".
- Click the "API Access" tab.
- Click the "Generate new access token" button to obtain an access token.
The access token must be sent with every API call in an HTTP authorization header (except for therequests to Get Access Token or Refresh Access Token). Once you have an access token, include it in the Authorization header for every request you make:
Authorization: Bearer JKlMNOpQ12RStUVwxYZAbcde3F5g6hijklM789The header name is Authorization and the value of the header is Bearer JKlMNOpQ12RStUVwxYZAbcde3F5g6hijklM789. Since the access token is being transmitted in clear text, all API calls are done over HTTPS.
NOTE: A best practice is to use a shared account, such as ticket-processor@example.com, rather than your individual work account.
API Connection Manager configuration
Just perform these simple steps to finish authentication configuration:
-
Set Authentication Type to
Static Token [Http] - Optional step. Modify API Base URL if needed (in most cases default will work).
- Fill in all the required parameters and set optional parameters if needed.
- Finally, hit OK button:
SmartsheetDSNSmartsheetStatic Token [Http]https://api.smartsheet.com/2.0Required Parameters Access Token Fill-in the parameter... Optional Parameters RetryMode RetryWhenStatusCodeMatch RetryStatusCodeList 429|503 RetryCountMax 5 RetryMultiplyWaitTime True
-
Once the data source connection has been configured, it's time to configure the SQL query. Select the Preview tab and then click Query Builder button to configure the SQL query:
ZappySys API Driver - SmartsheetRead and write Smartsheet data effortlessly. Integrate, manage, and automate sheets, rows, and reports — almost no coding required.SmartsheetDSN
-
Start by selecting the Table or Endpoint you are interested in and then configure the parameters. This will generate a query that we will use in Alteryx to retrieve data from Smartsheet. Hit OK button to use this query in the next step.
SELECT * FROM Sheets --Where Id='5815807987847055'
Some parameters configured in this window will be passed to the Smartsheet API, e.g. filtering parameters. It means that filtering will be done on the server side (instead of the client side), enabling you to get only the meaningful datamuch faster . -
Now hit Preview Data button to preview the data using the generated SQL query. If you are satisfied with the result, use this query in Alteryx:
ZappySys API Driver - SmartsheetRead and write Smartsheet data effortlessly. Integrate, manage, and automate sheets, rows, and reports — almost no coding required.SmartsheetDSNSELECT * FROM Sheets --Where Id='5815807987847055'
You can also access data quickly from the tables dropdown by selecting <Select table>.AWHEREclause,LIMITkeyword will be performed on the client side, meaning that thewhole result set will be retrieved from the Smartsheet API first, and only then the filtering will be applied to the data. If possible, it is recommended to use parameters in Query Builder to filter the data on the server side (in Smartsheet servers). -
Click OK to finish creating the data source.
Video Tutorial
Read Smartsheet data in Alteryx Designer (workstation)
Here we will be reading Smartsheet data on your workstation using Alteryx Designer. Follow the steps below to connect via ODBC and run your workflow locally.
-
Open Alteryx Designer.
-
First, verify your DCM Settings to ensure you can access ODBC drivers. Go to Options > User Settings > Edit User Settings.
If DCM Mode is set to DCM Only, change it to DCM Optional if you would like to access the legacy Generic ODBC Connection.
After changing this setting, you may need to click Save and restart the connection window for the "Generic ODBC" icon to appear. -
Drag an Input Data tool onto your Alteryx canvas.
-
In the Configuration pane, click Set Up a Connection.
-
Note for DCM Users: If your environment has DCM (Data Connection Manager) enabled, the classic "Generic ODBC" icon may be hidden. To find it, select Data sources on the left and type "ODBC" in the search bar.
-
Once the ODBC window opens, click Connect Asset and select your SmartsheetDSN DSN from the list.
Ensure you have configured a 64-bit System DSN in the Windows ODBC Data Source Administrator before this step. -
After selecting your DSN, configure your SQL Query in the Input Data tool configuration:
-
To save your data, drag an Output Data tool and connect it to the Input Data tool.
-
Configure the Output Data tool to write to a CSV file:
-
Press Run (Ctrl+R) to execute the workflow. Verify the results in the Results Window at the bottom.
Using DSN-less Connection String
If you prefer to use a DSN-less connection string instead of creating an ODBC data source in Alteryx, you can enter the connection string directly in the Input Data tool's connection setup:
Deploy workflow and run on server (e.g. Alteryx Server)
To run your Alteryx workflow on a server (e.g. Alteryx Server or a machine used for scheduled runs), install ZappySys ODBC PowerPack and configure the same DSN on that server so the workflow can connect to Smartsheet data.
- On the server where the workflow will run, download and install ODBC PowerPack (v2.2.1 or higher for Alteryx support).
- Open ODBC Data Sources (64-bit) on the server and create a System DSN with the same name and settings as on your workstation (use the same driver and connection configuration). An easy way to copy your workstation DSN settings to the server is described in How to copy ODBC DSN or Data Gateway settings to another server (use Copy Settings on the workstation, then Load settings on the server).
- Deploy or publish your workflow to the server (e.g. upload to Alteryx Server or copy the workflow to the server).
- Run the workflow on the server; it will use the DSN you created in step 2 to connect to Smartsheet.
Optional: Centralized data access via ZappySys Data Gateway
In some situations, you may need to provide Smartsheet data access to multiple users or services. Configuring the data source on a Data Gateway creates a single, centralized connection point for this purpose.
This configuration provides two primary advantages:
-
Centralized data access
The data source is configured once on the gateway, eliminating the need to set it up individually on each user's machine or application. This significantly simplifies the management process.
-
Centralized access control
Since all connections route through the gateway, access can be governed or revoked from a single location for all users.
| Data Gateway |
Local ODBC
data source
|
|
|---|---|---|
| Simple configuration | ||
| Installation | Single machine | Per machine |
| Connectivity | Local and remote | Local only |
| Connections limit | Limited by License | Unlimited |
| Central data access | ||
| Central access control | ||
| More flexible cost |
To achieve this, you must first create a data source in the Data Gateway (server-side) and then create an ODBC data source in Alteryx (client-side) to connect to it.
Let's not wait and get going!
Create Smartsheet data source in the gateway
In this section we will create a data source for Smartsheet in the Data Gateway. Let's follow these steps to accomplish that:
-
Search for
gatewayin the Windows Start Menu and open ZappySys Data Gateway Configuration:
-
Go to the Users tab and follow these steps to add a Data Gateway user:
- Click the Add button
-
In the Login field enter a username, e.g.,
john - Then enter a Password
- Check the Is Administrator checkbox
- Click OK to save
-
Now we are ready to add a data source:
- Click the Add button
- Give the Data source a name (have it handy for later)
- Then select Native - ZappySys API Driver
- Finally, click OK
SmartsheetDSNZappySys API Driver
-
When the ZappySys API Driver configuration window opens, go back to ODBC Data Source Administrator where you already have the Smartsheet ODBC data source created and configured, and follow these steps on how to Import data source configuration into the Gateway:
-
Open ODBC data source configuration and click Copy settings:
ZappySys API Driver - SmartsheetRead and write Smartsheet data effortlessly. Integrate, manage, and automate sheets, rows, and reports — almost no coding required.SmartsheetDSN
-
The window opens, telling us the connection string was successfully copied to the clipboard:
-
Then go to Data Gateway configuration and in data source configuration window click Load settings:
SmartsheetDSNZappySys API Driver - Configuration [Version: 2.0.1.10418]ZappySys API Driver - SmartsheetRead and write Smartsheet data effortlessly. Integrate, manage, and automate sheets, rows, and reports — almost no coding required.SmartsheetDSN
-
Once a window opens, just paste the settings by pressing
CTRL+Vor by clicking right mouse button and then Paste option.
-
Open ODBC data source configuration and click Copy settings:
-
Once done, go to the Network Settings tab and Add a firewall rule for inbound traffic:
- This will initially allow all inbound traffic.
- Click Edit IP filters to restrict access to specific IP addresses or ranges.
-
Crucial Step: After creating or modifying the data source, you must:
- Click the Save button to persist your changes.
- Hit Yes when prompted to restart the Data Gateway service.
This ensures all changes are properly applied:
Skipping this step may cause the new settings to fail, preventing you from connecting to the data source.
Create ODBC data source to connect to the gateway
In this part we will create an ODBC data source to connect to the ZappySys Data Gateway from Alteryx. To achieve that, let's perform these steps:
-
Search for
odbcand open the ODBC Data Sources (64-bit):
-
Create a User data source (User DSN) based on the ODBC Driver 17 for SQL Server driver:
ODBC Driver 17 for SQL Server
If you don't see the ODBC Driver 17 for SQL Server driver in the list, choose a similar version. -
Then set a Name for the data source (e.g.
Gateway) and the address of the Data Gateway:ZappySysGatewayDSNlocalhost,5000
Make sure you separate the hostname and port with a comma, e.g.localhost,5000. -
Proceed with the authentication part:
- Select SQL Server authentication
-
In the Login ID field enter the user name you created in the Data Gateway, e.g.,
john - Set Password to the one you configured in the Data Gateway
-
Then set the default database property to
SmartsheetDSN(the one we used in the Data Gateway):SmartsheetDSNSmartsheetDSN
Make sure to type the data source name manually or copy/paste it directly into the field. Using the dropdown might fail because the Trust server certificate option is not enabled yet (next step). -
Continue by checking the Trust server certificate option:
-
Once you do that, test the connection:
-
If the connection is successful, everything is good:
-
Done!
We are ready to move to the final step. Let's do it!
Access data in Alteryx via the gateway
Finally, we are ready to read data from Smartsheet in Alteryx via the Data Gateway. Follow these final steps:
-
Go back to Alteryx.
-
Drag an Input Data tool onto your Alteryx canvas.
-
In the Configuration pane, click Set Up a Connection.
-
Note for DCM Users: If your environment has DCM (Data Connection Manager) enabled, the classic "Generic ODBC" icon may be hidden. To find it, select Data sources on the left and type "ODBC" in the search bar.
-
Once the ODBC window opens, click Connect Asset and select your ZappySysGatewayDSN DSN from the list.
Ensure you have configured a 64-bit System DSN in the Windows ODBC Data Source Administrator before this step. -
Read the data the same way we discussed at the beginning of this article.
-
That's it!
Now you can connect to Smartsheet data in Alteryx via the Data Gateway.
john and your password.
Supported Smartsheet Connector actions
Got a specific use case in mind? We've mapped out exactly how to perform a variety of essential Smartsheet operations directly in Alteryx, so you don't have to figure out the setup from scratch. Check out the step-by-step guides below:
- Add Sheet Rows
- Delete Sheet Rows
- Export Report (to PDF, Excel, CSV file)
- Export Sheet (to PDF, Excel, CSV file)
- Get Contacts
- Get Sheet Fields
- Get Sheet Row by ID(s)
- Get Sheet Rows
- List Contacts
- List Groups
- List Reports
- List Sheets
- Search (cell data or other object types)
- Send Report Via Email Excel Pdf Or Pdf Gantt Format
- Send Sheet Via Email Excel Pdf Or Pdf Gantt Format
- Update Sheet Rows
- Make Generic REST API Request
- Make Generic REST API Request (Bulk Write)
Conclusion
In this article we showed you how to connect to Smartsheet in Alteryx and integrate data without writing complex code — all of this was powered by Smartsheet ODBC Driver.
Download ODBC PowerPack now or ping us via chat if you have any questions or are looking for a specific feature (you can also reach out to us by submitting a ticket):